Condo Fan Coil Unit Repair, Installation, Maintenance & Replacement in Toronto GTA Ontario. Condominium HVAC Services.

Your Greater Toronto Area’s Condominium HVAC Contractors.

Condo Fan Coil Unit Repair, Installation & Replacement Services

Condominium HVAC Services in Toronto GTA Ontario, Fan Coil Unit Services

Commodore Group offers a variety of services related to the repair, maintenance, retrofit, and replacement of condo fan coil units in Toronto and the Greater Toronto Area (GTA). Our team of certified and insured HVAC technicians can handle all types of fan coil systems, including horizontal and vertical models, and can troubleshoot issues such as insufficient airflow or improper heating or cooling. We also offer maintenance services to ensure the proper functioning of your fan coil unit, including replacing air filters and checking for water leaks. In addition, we can retrofit or replace older fan coils to improve their efficiency and performance without causing damage to surrounding walls or structures. If you’re experiencing problems with your fan coil unit or want to schedule maintenance or retrofit services, please contact us for more information. Some of our condo Fan Coil Unit repair, installation and replacement services are:

  • Condo Fan Coil Unit System Inspection & Report
  • Condo Fan Coil Unit Repair Services
  • Condo Fan Coil Unit Annual Maintenance
  • Condo Fan Coil Unit Retrofit & Upgrade
  • Condo Fan Coil Unit Installation & Replacement
  • Condo Fan Coil Unit Parts & Warranty
  • High Rise Fan Coil Unit Systems
our licensed condominium hvac techs doing a Condo fan coil unit repair & installation service

Condo Fan Coil Unit Repair, Installation & Replacement Services

Condominium HVAC Services in Toronto GTA Ontario
condo heat pump repair

Condo Fan Coil Unit Repair, Installation & Replacement Services

Condominium HVAC Services in Toronto GTA Ontario
our licensed condominium hvac techs doing a Condo fan coil unit replacement

Condo Fan Coil Unit Repair, Installation & Replacement Services

Condominium HVAC Services in Toronto GTA Ontario
Condo Fan Coil Unit Repair, Installation, Maintenance & Replacement in Toronto GTA Ontario. Condominium HVAC Services.

High Rise Condominium Fan Coil Unit Services

Free Estimate Condo Fan Coil Unit Installation & Replacement in Toronto GTA Ontario

We Are Certified High Rise Condominium HVAC Contractors Servicing Residential Commercial and Industrial Areas. We Will Provide You with A Free Estimate for Any New Condo HVAC Project in Toronto GTA Ontario.

Condo Fan Coil Unit Retrofit & Replacement in Toronto GTA Ontario

Fan coil unit retrofits can be a convenient and cost-effective way to upgrade your HVAC system without the need for extensive renovations or damage to surrounding walls. Retrofitting involves replacing the internal components of the unit, such as the fan, coil, and thermostat, while keeping the existing cabinet in place. This can be a particularly useful option in older buildings where the existing cabinet may be in good condition but the internal components have become outdated or malfunctioning.

One advantage of fan coil unit retrofits is that they can be completed relatively quickly, often in a matter of hours or a few days, depending on the complexity of the installation. This can be a significant advantage over traditional replacements, which often require the removal of the old unit and the installation of a new one, which can take much longer and cause more disruption.

Another benefit of fan coil unit retrofits is that they can be less expensive than traditional replacements, as they do not require the removal and disposal of the old unit or the installation of a new cabinet. This can make retrofits a more cost-effective option for buildings looking to upgrade their HVAC systems without incurring the full cost of a traditional replacement.

FAQs: Condo Fan Coil Unit Repair & Installation Services

Some answers for the common questions about Condo Fan Coil Unit repair and installation

  • Turn the fan coil unit off and wait until it has cooled down.
  • Remove the panel.
  • Use a brush head on a vacuum cleaner to remove dust.
  • Use a dry cloth to clean the casing.
  • Replace the panel when finished cleaning the coils.

A fan coil unit can last up to 10 or 15 years with regular maintenance, but there are several indications that it’s time to replace it.

Replacing the air filters is a straightforward task, and should be done every three months as a minimum. Some homeowners change the air filter monthly depending on their circumstances.

Fan coil units range from $300 to $3,500, depending on the size and type. The term is often used interchangeably with air handlers, but fan coil units are not always the same thing. The least-expensive models run $300 to $800.

There are four types of fan coil units (FCUs); horizontal chassis above a ceiling void, horizontal exposed, underfloor and vertical wall mounted units.

A fan coil unit (FCU), also known as a Vertical Fan Coil-Unit (VFC), is a device consisting of a heat exchanger (coil) and a fan.

A chilled water fan coil unit (FCU) works by transferring heat from the air passing over the internal heat exchanger to the chilled water passing within. Cold water is supplied by a chiller unit, or reversible heat pump, which is installed in a central plant room or on the roof of a building.

Fan Coil Actuator is responsible to control the valves in order to open and close the system’s when it’s called for heating & cooling via the thermostat. This is done by letting the water into the coils when you set your thermostat either for heating or cooling.

The fan coil actuator permits the electrical control of one or two fan coil units. … Depending on the design of the device, fan coil units are used in 2. pipe systems (heating only, cooling only, or heating and cooling via a common piping system) or alternatively in 4.

Generally, for a full installation, FCU, ducts, grilles, pipework, etc. would expect from 1-2 days.

Protect your Heating and Cooling Coils with Fan Coil Filters. These filters are designed to stop large particles from building up on your Heating/Cooling Coils. The Build up of Dust Particles can reduce the efficiency of your coils. Robust.

Hydronic air handlers, also known as hydronic fan coils or hot/chilled water fan coils, are devices that take the heat from hot water and transfer it to a forced air duct. This is done with a water-to-air heat exchanger, and a blower. Forced air cooling can also be accomplished from chilled water in the same manner.

4 pipe fan coil systems have two water loops (hot and chilled water) throughout the building connected to each fan coil. The water loops are insulated. Providing heating and cooling with water has a very low transportation (pump work) cost making fan coils an energy-efficient system choice.

An FCU will generally consist of the following components:

  • Cased or Uncased [casing around unit]
  • Air Intake.
  • Filter.
  • Fan.
  • Cooling Coil [water/dx]
  • Heating Coil [water/electric]
  • Discharge.
  • Grille [intake/discharge]

AHU, completely known as air handling unit is different from FCU or the fan coil unit. AHUs are usually connected to a central HVAC system whereas an FCU can function or be installed itself. … It is only composed of a simple coil and fan. Ordinarily, AHUs have certain features that are not present in the FCU type.

The Fan Coil Unit is controlled by a unit mounted controller provided by Mechanical Systems Controls Contractor (MSCC). B. On a call for cooling, the thermostat signals for the heating control valve to modulate toward the closed position.

A fan coil unit (FCU) is a device that uses a coil and a fan to heat or cool a room without connecting to ductwork. Indoor air moves over the coil, which heats or cools the air before pushing it back out into the room.

FCUs use a coil and fan to heat or cool a room. Indoor air moves over the coil to be heated or cooled before being released into the room. These thermostats allow for multiple settings of the fan’s output to gradually heat or cool the room to the desired temperature.

FCU systems are of average efficiency only but if well maintained and operated can produce a good level of efficiency. They are generally not as efficient as standard alternatives such as variable volume air conditioning, chilled beams and displacement systems.

A 2 Pipe Fan coil system is a single closed loop supply and return water distribution system that serves each suite. The building has a central chiller and cooling tower to cool the water in the loop and a Boiler to heat the water in. the loop. There is only one water loop for the building.

Fan coil units and unit ventilators served by a two-pipe system contain only one coil which serves as the heating and cooling coil, depending upon the system. The four-pipe system includes a distribution system that contains both hot water supply with return lines and a chilled water supply with return lines.

The 4 pipe system has two available sources (heating and cooling) which makes the fan coil independent of the system mode. Unlike to the 2 pipe system, it can cool and heat at the same time allowing for dehumidification to occur. This is the configuration required when setting up an analog valve in a 2 pipe fan coil.

Mold growth in fan coil units can be caused by a variety of factors, including inadequate maintenance, poor ventilation, and high humidity levels.

One of the main causes of mold growth in fan coil units is inadequate maintenance. If the unit is not regularly cleaned and maintained, dust and dirt can accumulate on the coils and other components, providing a breeding ground for mold. Additionally, if the unit is not properly drained or the drain lines are clogged, water can accumulate inside the unit, leading to mold growth.

Another common cause of mold growth in fan coil units is poor ventilation. If the unit is located in a poorly ventilated area or if the ventilation in the unit is not functioning properly, moisture and humidity can build up inside the unit, leading to mold growth.

Finally, high humidity levels can also contribute to mold growth in fan coil units. If the humidity level in the unit is consistently above 60%, mold can grow and thrive. To prevent mold growth, it’s important to maintain proper humidity levels in the unit by using a dehumidifier or other moisture control measures.

24-Hour Emergency Condo Fan Coil Unit Repair Services in Toronto GTA Ontario

Emergency Condominium Fan Coil Unit Repair Services

24-Hour Emergency Condo Fan Coil Unit Repair Services in Toronto GTA Ontario

We Are Certified High Rise Condominium HVAC Contractors Servicing Residential Commercial and Industrial Areas. We Will Provide You with A Free Estimate for Any New Condo HVAC Project Work in Toronto GTA Ontario.